15 resultados para diagnostics

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over the last three decades, sensors based on the phenomenon of surface plasmon resonance have proven particularly suitable for real time thin film characterization, gas detection, biomolecular interaction examination and to supplement electrochemical methods. Systems based on prism coupling have been combined with fluorescence detection under the name of surface plasmon fluorescence spectroscopy to increase sensitivity even further. Alternatively, metal gratings can be employed to match photons for plasmon resonance. The real time monitoring of binding reactions not yet been reported in the combination of fluorescence detection and grating coupling. Grating-based systems promise more competitive products, because of reduced operating costs, and offer benefits for device engineering. This thesis is comprised of a comprehensive study of the suitability of grating coupling for fluorescence based analyte detection. Fundamental properties of grating coupled surface plasmon fluorescence spectroscopy are described, as well as issues related to the commercial realization of the method. Several new experimental techniques are introduced and demonstrated in order to optimize performance in certain areas and improve upon capabilities in respect to prism-based systems. Holographically fabricated gratings are characterized by atomic force microscopy and optical methods, aided by simulations and profile parameters responsible for efficient coupling are analyzed. The directional emission of fluorophores immobilized on a grating surface is studied in detail, including the magnitude and geometry of the fluorescence emission pattern for different grating constants and polarizations. Additionally, the separation between the minimum of the reflected intensity and the maximum fluorescence excitation position is examined. One of the key requirements for the commercial feasibility of grating coupling is the cheap and faithful mass production of disposable samples from a given master grating. The replication of gratings is demonstrated by a simple hot embossing method with good reproducibility to address this matter. The in-situ fluorescence detection of analyte immobilization and affinity measurements using grating coupling are described for the first time. The physical factors related to the sensitivity of the technique are assessed and the lower limit of detection of the technique is determined for an exemplary assay. Particular attention is paid to the contribution of bulk fluorophores to the total signal in terms of magnitude and polarization of incident and emitted light. Emission from the bulk can be a limiting factor for experiments with certain assay formats. For that reason, a novel optical method, based on the modulation of both polarization and intensity of the incident beam, is introduced and demonstrated to be capable of eliminating this contribution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray laser fluorescence spectroscopy of the 2s-2p transition in Li-like ions is promising to become a widely applicable tool to provide information on the nuclear charge radii of stable and radioactive isotopes. For performing such experiments at the Experimental Storage Ring ESR, and the future NESR within the FAIR Project, a grazing incidence pumped (GRIP) x-ray laser (XRL) was set up at GSI Darmstadt using PHELIX (Petawatt High Energy Laser for heavy Ions eXperiments). The experiments demonstrated that lasing using the GRIP geometry could be achieved with relatively low pump energy, a prerequisite for higher repetition rate. In the first chapter the need of a plasma XRL is motivated and a short history of the plasma XRL is presented. The distinctive characteristic of the GRIP method is the controlled deposition of the pump laser energy into the desired plasma density region. While up to now the analysis performed were mostly concerned with the plasma density at the turning point of the main pump pulse, in this thesis it is demonstrated that also the energy deposition is significantly modified for the GRIP method, being sensitive in different ways to a large number of parameters. In the second chapter, the theoretical description of the plasma evolution, active medium and XRL emission properties are reviewed. In addition an innovative analysis of the laser absorption in plasma which includes an inverse Bremsstrahlung (IB) correction factor is presented. The third chapter gives an overview of the experimental set-up and diagnostics, providing an analytical formula for the average and instantaneous traveling wave speed generated with a tilted, on-axis spherical mirror, the only focusing system used up to now in GRIP XRL. The fourth chapter describes the experimental optimization and results. The emphasis is on the effect of the incidence angle of the main pump pulse on the absorption in plasma and on output and gain in different lasing lines. This is compared to the theoretical results for two different incidence angles. Significant corrections for the temperature evolution during the main pump pulse due to the incidence angle are demonstrated in comparison to a simple analytical model which does not take into account the pumping geometry. A much better agreement is reached by the model developed in this thesis. An interesting result is also the appearance of a central dip in the spatially resolved keV emission which was observed in the XRL experiments for the first time and correlates well with previous near field imaging and plasma density profile measurements. In the conclusion also an outlook to the generation of shorter wavelength XRL’s is given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Untersuchungen zur stereokontrollierten Synthese von 3-Mercaptolysinderivaten: 3-Mercaptolysin und Peptide mit einer 3-Mercaptolysin-Einheit sind als Liganden für Nukleardiagnostika in der Kontrastmittelforschung von großem Interesse. Für das Screening Gewebe-selektiver Diagnostika sollten Mercaptolysinderivate, die sich für den Einbau in Peptide eignen, stereokontrolliert aufgebaut werden. Als Grundlage wurde im Rahmen dieser Arbeit eine sehr effiziente Synthese von Methoxymethyl-(4-oxo-butyl)-carbaminsäure-tert-butylester aus Pent-4-en-1-ol entwickelt. Nach Olefinierung des Aldehyds konnten Auxiliar-substituierte 6-Amino-hexensäure-derivate in guten Ausbeuten erhalten werden. Diese bildeten die Startmaterialien für auxiliargesteuerte Aziridinierungen mit anschließender Ringöffnung durch Schwefel-Nukleophile. Zudem wurden Azidierungen an Auxiliar-bewehrten Substraten, Michael-Additionen von Schwefel-Nukleophilen an Dehydroaminosäuren und viele weitere Reaktionen untersucht. Es galt dabei auf patentrechtlich geschützte Reaktionen zu verzichten, weil die Produkte ggf. in großem Maßstab kommerziell genutzt werden sollen. Dabei konnten alle vier stereoisomeren 2-Acetylamino-6-(tert-butoxycarbonyl-methoxymethyl-amino)-3-(4-methoxy-benzylsulfanyl)-hexansäurementhylester in guter Ausbeute synthetisiert werden. Nach Herstellung größerer Mengen der entsprechenden am Schwefelatom ungeschützten N-Fmoc-Aminosäurederivate sollen alle vier Stereoisomere in Peptide eingebaut und auf ihre Eignung als Liganden in Nukleardiagnostika untersucht werden. Untersuchungen zur Synthese neuartiger Ansa-Steroide: Über die Synthese von Ansa-Seco-Steroiden mittels eine Kaskade von intermolekularer Diels-Alder-Reaktion und anschließender Retro-Diels-Alder-Reaktion an 5,6,7,8-Tetradehydrosteroiden wurde erstmals 1986 von E. Winterfeldt et al. berichtet. Die damit eröffnete Möglichkeit eines völlig neuen Zugangs zu pharmakologisch interessanten Makrolid-Substraten konnte aber bislang nicht effektiv genutzt werden, weil insbesondere im Zusammenhang mit der Diels-Alder-Reaktion erhebliche präparative Probleme auftraten: Brauchbare Reaktivität nur bei sehr wenigen Dienophilen, Regioselektivitätsprobleme, etc. Hier galt es zu untersuchen, inwiefern sich diese Probleme durch die intramolekulare Reaktionsführung der Cycloaddition unterdrücken lassen können. Für die intramolekulare Diels-Alder-Reaktion zwischen der 5,7-Dien-Einheit des Steroids und einer an das Substrat gebundenen Dienophil-Einheit ist die Möglichkeit einer günstigen Anordnung der beiden Reaktanden-Gruppen entscheidend. Dafür wurden umfangreiche Untersuchungen zur alpha-konfigurierten Anbindung eines Dienophils in die 3-Position an 3-Hydroxy-5,6,7,8-Tetradehydrosteroiden durchgeführt: Mitsunobu-Reaktionen, Oxidations-Reduktions-Sequenzen, Oxidations-Ketalisierungs-Sequenzen, etc. Hierbei wurden zahlreiche neue Steroide synthetisiert. Es gelang jedoch nicht, 5,6,7,8-Tetradehydrosteroide mit axial in Position 3 eingebundenen Dienophilen in präparativ nutzbaren Mengen zu synthetisieren. Bei der Untersuchung intermolekularer Diels-Alder-Reaktionen zwischen Ergosterol und Brommaleinsäureanhydrid wurde vorzugsweise die Bildung der Addukte des 7,8,14,15-Tetradehydroisomers des Ergosterols beobachtet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Elektrische Impedanztomographie soll als kostengünstige und nebenwirkungsfreie Tomographiemethode in der medizinischen Diagnostik, z. B. in der Mammographie dienen. Mit der EIT läßt sich Krebsgewebe von gesundem Gewebe unterscheiden, da es eine signifikant erhöhte Leitfähigkeit aufweist. Damit kann die EIT als Ergänzung zu den klassischen Diagnoseverfahren dienen. So ist z.B. bei jungen Frauen mit einem dichteren Fettgewebe die Identifizierung eines Mammakarzinoms mit der Röntgentomographie nicht immer möglich. Ziel dieser Arbeit war es, einen Prototypen für die Impedanztomographie zu entwickeln und mögliche Anwendungen zu testen. Der Tomograph ist in Zusammenarbeit mit Dr. K.H.Georgi gebaut worden. Der Tomograph erlaubt es niederohmige, Wechselströme an Elektroden auf der Körperoberfläche einzuspeisen. Die Potentiale können an diesen Elektroden programmierbar vorgegeben werden. Weitere hochohmige Elektroden dienen zur Potentialmessung. Um den Hautwiderstand zu überbrücken, werden Wechselstromfrequenzen von 20-100 kHz eingesetzt. Mit der Möglichkeit der Messung von Strom und Potential auf unterschiedlichen Elektroden kann man das Problem des nur ungenau bekannten Hautwiderstandes umgehen. Prinzipiell ist es mit dem Mainzer EIT System möglich, 100 Messungen in der Sekunde durchzuführen. Auf der Basis von mit dem Mainzer EIT gewonnenen Daten sollten unterschiedliche Rekonstruktionsalgorithmen getestet und weiterentwickelt werden. In der Vergangenheit sind verschiedene Rekonstruktionsalgorithmen für das mathematisch schlecht gestellte EIT Problem betrachtet worden. Sie beruhen im Wesentlichen auf zwei Strategien: Die Linearisierung und iterative Lösung des Problems und Gebietserkennungsmethoden. Die iterativen Verfahren wurden von mir dahingehend modifiziert, dass Leitfähigkeitserhöhungen und Leitfähigkeitserniedrigungen gleichberechtigt behandelt werden können. Für den modifizierten Algorithmus wurden zwei verschiedene Rekonstruktionsalgorithmen programmiert und mit synthetischen Daten getestet. Zum einen die Rekonstruktion über die approximative Inverse, zum anderen eine Rekonstruktion mit einer Diskretisierung. Speziell für die Rekonstruktion mittels Diskretisierung wurde eine Methode entwickelt, mit der zusätzliche Informationen in der Rekonstruktion berücksichtigt werden können, was zu einer Verbesserung der Rekonstruktion beiträgt. Der Gebietserkennungsalgorithmus kann diese Zusatzinformationen liefern. In der Arbeit wurde ein neueres Verfahren für die Gebietserkennung derart modifiziert, dass eine Rekonstruktion auch für getrennte Strom- und Spannungselektroden möglich wurde. Mit Hilfe von Differenzdaten lassen sich ausgezeichnete Rekonstruktionen erzielen. Für die medizinischen Anwendungen sind aber Absolutmessungen nötig, d.h. ohne Leermessung. Der erwartende Effekt einer Inhomogenität in der Leitfähigkeit ist sehr klein und als Differenz zweier grosser Zahlen sehr schwierig zu bestimmen. Die entwickelten Algorithmen kommen auch gut mit Absolutdaten zurecht.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Physicochemical experimental techniques combined with the specificity of a biological recognition system have resulted in a variety of new analytical devices known as biosensors. Biosensors are under intensive development worldwide because they have many potential applications, e.g. in the fields of clinical diagnostics, food analysis, and environmental monitoring. Much effort is spent on the development of highly sensitive sensor platforms to study interactions on the molecular scale. In the first part, this thesis focuses on exploiting the biosensing application of nanoporous gold (NPG) membranes. NPG with randomly distributed nanopores (pore sizes less than 50 nm) will be discussed here. The NPG membrane shows unique plasmonic features, i.e. it supports both propagating and localized surface plasmon resonance modes (p SPR and l-SPR, respectively), both offering sensitive probing of the local refractive index variation on/in NPG. Surface refractive index sensors have an inherent advantage over fluorescence optical biosensors that require a chromophoric group or other luminescence label to transduce the binding event. In the second part, gold/silica composite inverse opals with macroporous structures were investigated with bio- or chemical sensing applications in mind. These samples combined the advantages of a larger available gold surface area with a regular and highly ordered grating structure. The signal of the plasmon was less noisy in these ordered substrate structures compared to the random pore structures of the NPG samples. In the third part of the thesis, surface plasmon resonance (SPR) spectroscopy was applied to probe the protein-protein interaction of the calcium binding protein centrin with the heterotrimeric G-protein transducin on a newly designed sensor platform. SPR spectroscopy was intended to elucidate how the binding of centrin to transducin is regulated towards understanding centrin functions in photoreceptor cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Durch globale Expressionsprofil-Analysen auf Transkriptom-, Proteom- oder Metabolom-Ebene können biotechnologische Produktionsprozesse besser verstanden und die Erkenntnisse für die zielgerichtete, rationale Optimierung von Expressionssystemen genutzt werden. In der vorliegenden Arbeit wurde die Überexpression einer Glukose-Dehydrogenase (EC 1.1.5.2), die von der Roche Diagnostics GmbH für die diagnostische Anwendung optimiert worden war, in Escherichia coli untersucht. Die Enzymvariante unterscheidet sich in sieben ihrer 455 Aminosäuren vom Wildtyp-Enzym und wird im sonst isogenen Wirt-/Vektor-System in signifikant geringeren Mengen (Faktor 5) gebildet. Das prokaryontische Expressionssystem wurde auf Proteom-Ebene charakterisiert. Die 2-dimensionale differenzielle Gelelektrophorese (DIGE) wurde zuvor unter statistischen Aspekten untersucht. Unter Berücksichtigung von technischen und biologischen Variationen, falsch-positiven (α-) und falsch-negativen (β-) Fehlern sowie einem daraus abgeleiteten Versuchsdesign konnten Expressionsunterschiede als signifikant quantifiziert werden, wenn sie um den Faktor ≥ 1,4 differierten. Durch eine Hauptkomponenten-Analyse wurde gezeigt, dass die DIGE-Technologie für die Expressionsprofil-Analyse des Modellsystems geeignet ist. Der Expressionsstamm für die Enzymvariante zeichnete sich durch eine höhere Variabilität an Enzymen für den Zuckerabbau und die Nukleinsäure-Synthese aus. Im Expressionssystem für das Wildtyp-Enzym wurde eine unerwartet erhöhte Plasmidkopienzahl nachgewiesen. Als potenzieller Engpass in der Expression der rekombinanten Glukose-Dehydrogenase wurde die Löslichkeitsvermittlung identifiziert. Im Expressionsstamm für das Wildtyp-Enzym wurden viele Proteine für die Biogenese der äußeren Membran verstärkt exprimiert. Als Folge dessen wurde ein sog. envelope stress ausgelöst und die Zellen gingen in die stationäre Wuchsphase über. Die Ergebnisse der Proteomanalyse wurden weiterführend dazu genutzt, die Produktionsleistung für die Enzymvariante zu verbessern. Durch den Austausch des Replikationsursprungs im Expressionsvektor wurde die Plasmidkopienzahl erhöht und die zelluläre Expressionsleistung für die diagnostisch interessantere Enzymvariante um Faktor 7 - 9 gesteigert. Um die Löslichkeitsvermittlung während der Expression zu verbessern, wurde die Plasmidkopienzahl gesenkt und die Coexpression von Chaperonen initiiert. Die Ausbeuten aktiver Glukose-Dehydrogenase wurden durch die Renaturierung inaktiven Produkts aus dem optimierten Expressionssystem insgesamt um einen Faktor von 4,5 erhöht. Somit führte im Rahmen dieser Arbeit eine proteombasierte Expressionsprofil-Analyse zur zielgerichteten, rationalen Expressionsoptimierung eines prokaryontischen Modellsystems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enhancing the sensitivity of nuclear magnetic resonance measurements via hyperpolarization techniques like parahydrogen induced polarization (PHIP) is of high interest for spectroscopic investigations. Parahydrogen induced polarization is a chemical method, which makes use of the correlation between nuclear spins in parahydrogen to create hyperpolarized molecules. The key feature of this technique is the pairwise and simultaneous transfer of the two hydrogen atoms of parahydrogen to a double or triple bond resulting in a population of the Zeeman energy levels different from the Boltzmann equation. The obtained hyperpolarization results in antiphase peaks in the NMR spectrum with high intensities. Due to these strong NMR signals, this method finds arnlot of applications in chemistry e.g. the characterization of short-lived reaction intermediates. Also in medicine it opens up the possibility to boost the sensitivity of medical diagnostics via magnetic labeling of active contrast agents. Thus, further examination and optimization of the PHIP technique is of significant importance in order to achieve the highest possible sensitivity gain.rnrnIn this work, different aspects concerning PHIP were studied with respect to its chemical and spectroscopic background. The first part of this work mainly focused on optimizing the PHIP technique by investigating different catalyst systems and developing new setups for the parahydrogenation. Further examinations facilitated the transfer of the generated polarization from the protons to heteronuclei like 13C. The second part of this thesis examined the possibility to transfer these results to different biologically active compounds to enable their later application in medical diagnostics. Onerngroup of interesting substances is represented by metabolites or neurotransmitters in mammalian cells. Other interesting substances are clinically relevant drugs like a barbituric acid derivative or antidepressant drugs like citalopram which were investigated with regard to their applicability for the PHIP technique and the possibility to achievernpolarization transfer to 13C nuclei. The last investigated substrate is a polymerizable monomer whose polymer was used as a blood plasma expander for trauma victims after the first half of the 20th century. In this case, the utility of the monomer for the PHIP technique as a basis for later investigations of a polymerization reaction using hyperpolarized monomers was examined.rnrnHence, this thesis covers the optimization of the PHIP technology, hereby combining different fields of research like chemical and spectroscopical aspects, and transfers the results to applications of real biologally acitve compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mit einem in dieser Arbeit entwickelten Diagnose-Werkzeug wird im Rahmenrneines einfachen mechanistischenModells die Residuumszirkulation in der Stratosphärernermittelt. Die Residuumszirkulation wird als eine Schlüsselgröße für diernKlimavariabilität der Stratosphäre angesehen. Für die Diagnose wird mit einemrnmechanistischem Modell die Ausbreitung und das Brechen planetarer Wellenrnbeschrieben und der daraus resultierende Wellenantrieb bestimmt. Dieser Wellenantriebrnwird verwendet, um mit der numerischen Lösung einer elliptischenrnDifferentialgleichung die Residuumszirkulation zu berechnen.rnDieses Diagnose-Werkzeug wird genutzt, um in atmosphärischen Reanalysedatenrnden Zusammenhang der Residuumszirkulation mit verschiedenen Modenrnstratosphärischer Klimavariabilität zu untersuchen. Während für unterschiedlichernPhasen der quasi-zweijährigen Schwingung und der Nordatlantischen Oszillationrndie Residuumszirkulation deutliche Unterschiede aufzeigt, kann ein Einflussrndes 11-jährigen Sonnenfleckenzyklus auf die Residuumszirkulation nichtrneindeutig nachgewiesen werden. Eine Datenstudie zeigt, dass in den WintermonatenrnDezember und Januar die Stärke der Residuumszirkulation mit derrnTemperatur der unteren polaren Stratosphäre signifikant korreliert ist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid and sensitive detection of chemical and biological analytes becomes increasingly important in areas such as medical diagnostics, food control and environmental monitoring. Optical biosensors based on surface plasmon resonance (SPR) and optical waveguide spectroscopy have been extensively pushed forward in these fields. In this study, we combine SPR, surface plasmon-enhanced fluorescence spectroscopy (SPFS) and optical waveguide spectroscopy with hydrogel thin film for highly sensitive detection of molecular analytes.rnrnA novel biosensor based on SPFS which was advanced through the excitation of long range surface plasmons (LRSPs) is reported in this study. LRSPs are special surface plasmon waves propagating along thin metal films with orders of magnitude higher electromagnetic field intensity and lower damping than conventional SPs. Therefore, their excitation on the sensor surface provides further increased fluorescence signal. An inhibition immunoassay based on LRSP-enhanced fluorescence spectroscopy (LRSP-FS) was developed for the detection of aflatoxin M1 (AFM1) in milk. The biosensor allowed for the detection of AFM1 in milk at concentrations as low as 0.6 pg mL-1, which is about two orders of magnitude lower than the maximum AFM1 residue level in milk stipulated by the European Commission legislation.rnrnIn addition, LRSPs probe the medium adjacent to the metallic surface with more extended evanescent field than regular SPs. Therefore, three-dimensional binding matrices with up to micrometer thickness have been proposed for the immobilization of biomolecular recognition elements with large surface density that allows to exploit the whole evanescent field of LRSP. A photocrosslinkable carboxymethyl dextran (PCDM) hydrogel thin film is used as a binding matrix, and it is applied for the detection of free prostate specific antigen (f-PSA) based on the LRSP-FS and sandwich immunoassay. We show that this approach allows for the detection of f-PSA at low femto-molar range, which is approximately four orders of magnitude lower than that for direct detection of f-PSA based on the monitoring of binding-induced refractive index changes.rnrnHowever, a three dimensional hydrogel binding matrix with micrometer thickness can also serve as an optical waveguide. Based on the measurement of binding-induced refractive index changes, a hydrogel optical waveguide spectroscopy (HOWS) is reported for a label-free biosensor. This biosensor is implemented by using a SPR optical setup in which a carboxylated poly(N-isoproprylacrylamide) (PNIPAAm) hydrogel film is attached on a metallic surface and modified by protein catcher molecules. Compared to regular SPR biosensor with thiol self-assembled monolayer (SAM), HOWS provides an order of magnitude improved resolution in the refractive index measurements and enlarged binding capacity owing to its low damping and large swelling ratio, respectively. A model immunoassay experiment revealed that HOWS allowed detection of IgG molecules with a 10 pM limit of detection (LOD) that was five-fold lower than that achieved for SPR with thiol SAM. For the high capacity hydrogel matrix, the affinity binding was mass transport limited.rnrnThe mass transport of target molecules to the sensor surface can play as critical a role as the chemical reaction itself. In order to overcome the diffusion-limited mass transfer, magnetic iron oxide nanoparticles were employed. The magnetic nanoparticles (MNPs) can serve both as labels providing enhancement of the refractive index changes, and “vehicles” for rapidly delivering the analytes from sample solution to an SPR sensor surface with a gradient magnetic field. A model sandwich assay for the detection of β human chorionic gonadotropin (βhCG) has been utilized on a gold sensor surface with metallic diffraction grating structure supporting the excitation of SPs. Various detection formats including a) direct detection, b) sandwich assay, c) MNPs immunoassay without and d) with applied magnetic field were compared. The results show that the highly-sensitive MNPs immunoassay improves the LOD on the detection of βhCG by a factor of 5 orders of magnitude with respect to the direct detection.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zusammenfassung rnIn der vorliegenden Arbeit wurden sechs VWF/FVIII Gerinnungsfaktorkonzentrate unterschiedlicher Chargen auf ihre ADAMTS13 Aktivität, Antigen und VWF Multimere untersucht. Grund dafür ist die Annahme, dass bei der Aufkonzentrierung des VWFs möglicherweise auch erhöhte Mengen an ADAMTS13 vorhanden sind. Wäre dies nachweisbar, könnten die entsprechenden Konzentrate auch Anwendung bei TTP Patienten finden. Neben den Gerinnungsfaktorkonzentraten wurden ebenfalls die zur Plasmapherese verwendeten Therapeutika FFP und s/d Plasma analysiert. Es soll getestet werden, ob Unterschiede hinsichtlich der Qualität zwischen den Präparaten bestehen und inwiefern die Blutgruppen eine Auswirkung auf die ADAMTS13 Aktivität/Antigen haben. Überdies wurde die Bedeutung von ADAMTS13 als wichtiges diagnostisches Merkmal im Rahmen der Gegenüberstellung von Patienten mit thrombotischen Mikroangiopathien erörtert. Alle angewandten Methoden wurden zudem kritisch miteinander verglichen und auf ihre Eignung für die klinische Diagnostik getestet. Zur Untersuchung der ADAMTS13 Aktivität kamen drei unterschiedliche Methoden zur Anwendung, die BCS-Methode nach Böhm und zwei FRET Kits (Technozym®ADAMTS13/ActifluorTMADAMTS13). Für die Bestimmung des ADAMTS13 Antigen wurde das Technozym®ADAMTS13 Kit verwendete als auch der Imubind®ELISA angewendet. Mittels der SDS-Gelelektrophorese konnten die VWF Multimere dargestellt werden. Die Untersuchungen konnten zeigen, dass nur in Haemate®P, deutlich höhere ADAMTS13 Aktivitäten (12,3% bzw. 470ng/ml) sowie ein physiologische Antigenwerte vorlagen. Die anderen Faktorkonzentrate wiesen entweder nur sehr geringe bzw. keine Aktivitäten auf. Das Antigen lag bei allen Konzentraten im nachweisbaren Bereich. Folglich ist ein Einsatz von Haemate®P bei der Therapie der TTP, insbesondere bei hereditären Formen sowie bei Kindern, die durch eine Plasmapherese stark belastet werden, und bei Schwangeren, könnten, in Erwägung zu ziehen und innerhalb der Klinik zu testen. Die Plasmapräparate FFP und Octaplas® wiesen in allen Untersuchungen ADAMTS13 Aktivitäten und Antigen im mittleren bis hohen physiologischen Bereich auf. Insbesondere bei Blutgruppe 0 ließ sich beiden Präparaten eine höhere ADAMTS13 Aktivität und Antigen gegenüber den drei anderen Blutgruppen darstellen. Insgesamt waren die interindividuellen Schwankungen bei FFP deutlich höher als bei Octaplas®, was sich in der unterschiedlichen Herstellung der Präparate begründen lässt. Octaplas® ist also genauso geeignet zur Plasmapherese bei der TTP wie FFP, kann jedoch aufgrund seiner intensiveren Virusinaktivierung eine größere Sicherheit aufweisen und stellt sich auch in der Klinik als nebenwirkungsärmer dar. Bei der Gegenüberstellung der thrombotischen Mikroangiopathien konnte gezeigt werden, dass eine verminderte ADAMTS13 Aktivität ein wichtiges Unterscheidungsmerkmal ist und auch während der Remission schon diagnostizierbar werden kann. Auf der Grundlage der labordiagnostischen Werte und dem klinischen Erscheinungsbild im akuten Schub und in der Remission konnte ein diagnostischer Algorithmus für den klinischen Alltag erstellt werden. In der Methodenvalidierung erwies sich der ActifluorTMADAMTS13 Kit als der beste Kit, da er innerhalb kürzester Zeit zuverlässige Werte in Standardeinheiten liefert. Nach neuesten Erkenntnissen, bei der eine Unterscheidung von ADAMTS13 Aktivitäten über und unter 5 % von großer prognostischer Bedeutung sind, ist die BCS-Methode nach Böhm mit einer unteren Nachweisgrenze von 6,2% zu ungenau und auch hinsichtlich ihres Zeitaufwandes eher ungünstig.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In den westlichen Industrieländern ist das Mammakarzinom der häufigste bösartige Tumor der Frau. Sein weltweiter Anteil an allen Krebserkrankungen der Frau beläuft sich auf etwa 21 %. Inzwischen ist jede neunte Frau bedroht, während ihres Lebens an Brustkrebs zu erkranken. Die alterstandardisierte Mortalitätrate liegt derzeit bei knapp 27 %.rnrnDas Mammakarzinom hat eine relative geringe Wachstumsrate. Die Existenz eines diagnostischen Verfahrens, mit dem alle Mammakarzinome unter 10 mm Durchmesser erkannt und entfernt werden, würden den Tod durch Brustkrebs praktisch beseitigen. Denn die 20-Jahres-Überlebungsrate bei Erkrankung durch initiale Karzinome der Größe 5 bis 10 mm liegt mit über 95 % sehr hoch.rnrnMit der Kontrastmittel gestützten Bildgebung durch die MRT steht eine relativ junge Untersuchungsmethode zur Verfügung, die sensitiv genug zur Erkennung von Karzinomen ab einer Größe von 3 mm Durchmesser ist. Die diagnostische Methodik ist jedoch komplex, fehleranfällig, erfordert eine lange Einarbeitungszeit und somit viel Erfahrung des Radiologen.rnrnEine Computer unterstützte Diagnosesoftware kann die Qualität einer solch komplexen Diagnose erhöhen oder zumindest den Prozess beschleunigen. Das Ziel dieser Arbeit ist die Entwicklung einer vollautomatischen Diagnose Software, die als Zweitmeinungssystem eingesetzt werden kann. Meines Wissens existiert eine solche komplette Software bis heute nicht.rnrnDie Software führt eine Kette von verschiedenen Bildverarbeitungsschritten aus, die dem Vorgehen des Radiologen nachgeahmt wurden. Als Ergebnis wird eine selbstständige Diagnose für jede gefundene Läsion erstellt: Zuerst eleminiert eine 3d Bildregistrierung Bewegungsartefakte als Vorverarbeitungsschritt, um die Bildqualität der nachfolgenden Verarbeitungsschritte zu verbessern. Jedes kontrastanreichernde Objekt wird durch eine regelbasierte Segmentierung mit adaptiven Schwellwerten detektiert. Durch die Berechnung kinetischer und morphologischer Merkmale werden die Eigenschaften der Kontrastmittelaufnahme, Form-, Rand- und Textureeigenschaften für jedes Objekt beschrieben. Abschließend werden basierend auf den erhobenen Featurevektor durch zwei trainierte neuronale Netze jedes Objekt in zusätzliche Funde oder in gut- oder bösartige Läsionen klassifiziert.rnrnDie Leistungsfähigkeit der Software wurde auf Bilddaten von 101 weiblichen Patientinnen getested, die 141 histologisch gesicherte Läsionen enthielten. Die Vorhersage der Gesundheit dieser Läsionen ergab eine Sensitivität von 88 % bei einer Spezifität von 72 %. Diese Werte sind den in der Literatur bekannten Vorhersagen von Expertenradiologen ähnlich. Die Vorhersagen enthielten durchschnittlich 2,5 zusätzliche bösartige Funde pro Patientin, die sich als falsch klassifizierte Artefakte herausstellten.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Folic acid, also known as vitamin B9, is the oxidized form of 5,6,7,8-tetrahydrofolate, which serves as methyl- or methylene donor (C1-building blocks) during DNA synthesis. Under physiological conditions the required amount of 5,6,7,8-tetrahydrofolate for survival of the cell is accomplished through the reduced folate carrier (RFC). In contrast, the supply of 5,6,7,8-tetrahydrofolate is insufficient under pathophysiological conditions of tumors due to an increased proliferation rate. Consequently, many tumor cells exhibit an (over)expression of the folate receptor. This phenomenon has been applied to diagnostics (PET, SPECT, MR) to image FR-positive tumors and on the other hand to treat malignancies related to a FR (over)expression. Based on this concept, a new 18F-labeled folate for PET imaging has been developed and was evaluated in vivo using tumor-bearing mice. The incorporation of oligoethylene spacers into the molecular structure led to a significant enhancement of the pharmacokinetics in comparison to previously developed 18F-folates. The liver uptake could be reduced by one sixth by remaining a tumor uptake of 3%ID/g leading to better contrast ratios. Encouraged by these results, a clickable 18F-labeled serine-based prosthetic group has been synthesized, again with the idea to improve the metabolic and pharmacokinetic profile of hydrophilic radiotracers. Therefore, an alkyne-carrying azido-functionalized serine derivative for coupling to biomolecules was synthesized and a chlorine leaving group for 18F-labeling, which could be accomplished using a microwave-assisted synthesis, a [K⊂2.2.2]+/carbonate system in DMSO. Radiochemical yields of 77±6% could be achieved.rnThe promising results obtained from the FR-targeting concept in the diagnostic field have been transferred to the boron neutron capture therapy. Therefore, a folate derivative was coupled to different boron clusters and cell uptake studies were conducted. The synthesis of the folate-boron clusters was straightforward. At first, a linker molecule based on maleic acid was synthesized, which was coupled to the boron cluster via Michael Addition of a thiol and alkene and subsequently coupled to the targeting moiety using CuAAC. The new conjugates of folate and boron clusters led to a significant increase of boron concentration in the cell of about 5-times compared to currently used and approved boron pharmaceuticals. rnMoreover, azido-folate derivatives were coupled to macromolecular carrier systems (pHPMA), which showed an enhanced and specific accumulation at target sites (up to 2.5-times) during in vivo experiments. A specific blockade could be observed up to 30% indicating an efficient targeting effect. A new kind of nanoparticles consisting of a PDLLA core and p((HPMA)-b-LMA)) as surfactants were developed and successfully radiolabeled via 18F-click chemistry in good RCYs of 8±3%rnThe nanoparticles were obtained via the miniemulsion technique in combination with solvent evaporation. The 18F-labeled nanoparticles were applied to in vivo testing using a mouse model. PET imaging showed a “mixed” biodistribution of low molecular weight as well as high molecular weight systems, indicating a partial loss of the 18F-labeled surfactant.rnIn conclusion, the presented work successfully utilized the FR-targeting concept in both, the diagnostic field (PET imaging) and for therapeutic approaches (BNCT, drug delivery systems). As a result, the high potential of FR-targeting in oncological applications has been shown and was confirmed by small animal PET imaging.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Das Institut für Kernphysik der Universität Mainz betreibt seit 1990 eine weltweit einzigartige Beschleunigeranlage für kern- und teilchenphysikalische Experimente – das Mainzer Mikrotron (MAMI-B). Diese Beschleunigerkaskade besteht aus drei Rennbahn-Mikrotrons (RTMs) mit Hochfrequenzlinearbeschleunigern bei 2.45 GHz, mit denen ein quasi kontinuierlicher Elektronenstrahl von bis zu 100 μA auf 855MeV beschleunigt werden kann.rnrnIm Jahr 1999 wurde die Umsetzung der letzten Ausbaustufe – ein Harmonisches Doppelseitiges Mikrotron (HDSM, MAMI-C) – mit einer Endenergie von 1.5 GeV begonnen. Die Planung erforderte einige mutige Schritte, z.B. Umlenkmagnete mit Feldgradient und ihren daraus resultierenden strahloptischen Eigenschaften, die einen großen Einfluss auf die Longitudinaldynamik des Beschleunigers haben. Dies erforderte die Einführung der „harmonischen“ Betriebsweise mit zwei Frequenzen der zwei Linearbeschleuniger.rnrnViele Maschinenparameter (wie z.B. HF-Amplituden oder -Phasen) wirken direkt auf den Beschleunigungsprozess ein, ihre physikalischen Größen sind indes nicht immer auf einfache Weise messtechnisch zugänglich. Bei einem RTM mit einer verhältnismäßig einfachen und wohldefinierten Strahldynamik ist das im Routinebetrieb unproblematisch, beim HDSM hingegen ist schon allein wegen der größeren Zahl an Parametern die Kenntnis der physikalischen Größen von deutlich größerer Bedeutung. Es gelang im Rahmen dieser Arbeit, geeignete Methoden der Strahldiagnose zu entwickeln, mit denen diese Maschinenparameter überprüft und mit den Planungsvorgaben verglichen werden können.rnrnDa die Anpassung des Maschinenmodells an eine einzelne Phasenmessung aufgrund der unvermeidlichen Messfehler nicht immer eindeutige Ergebnisse liefert, wird eine Form der Tomographie verwendet. Der longitudinale Phasenraum wird dann in Form einer Akzeptanzmessung untersucht. Anschließend kann ein erweitertes Modell an die gewonnene Datenvielfalt angepasst werden, wodurch eine größere Signifikanz der Modellparameter erreicht wird.rnrnDie Ergebnisse dieser Untersuchungen zeigen, dass sich der Beschleuniger als Gesamtsystem im Wesentlichen wie vorhergesagt verhält und eine große Zahl unterschiedlicher Konfigurationen zum Strahlbetrieb möglich sind – im Routinebetrieb wird dies jedoch vermieden und eine bewährte Konfiguration für die meisten Situationen eingesetzt. Das führt zu einer guten Reproduzierbarkeit z.B. der Endenergie oder des Spinpolarisationswinkels an den Experimentierplätzen.rnrnDie Erkenntnisse aus diesen Untersuchungen wurden teilweise automatisiert, so dass nun den Operateuren zusätzliche und hilfreiche Diagnose zur Verfügung steht, mit denen der Maschinenbetrieb noch zuverlässiger durchgeführt werden kann.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biosensors find wide application in clinical diagnostics, bioprocess control and environmental monitoring. They should not only show high specificity and reproducibility but also a high sensitivity and stability of the signal. Therefore, I introduce a novel sensor technology based on plasmonic nanoparticles which overcomes both of these limitations. Plasmonic nanoparticles exhibit strong absorption and scattering in the visible and near-infrared spectral range. The plasmon resonance, the collective coherent oscillation mode of the conduction band electrons against the positively charged ionic lattice, is sensitive to the local environment of the particle. I monitor these changes in the resonance wavelength by a new dark-field spectroscopy technique. Due to a strong light source and a highly sensitive detector a temporal resolution in the microsecond regime is possible in combination with a high spectral stability. This opens a window to investigate dynamics on the molecular level and to gain knowledge about fundamental biological processes.rnFirst, I investigate adsorption at the non-equilibrium as well as at the equilibrium state. I show the temporal evolution of single adsorption events of fibrinogen on the surface of the sensor on a millisecond timescale. Fibrinogen is a blood plasma protein with a unique shape that plays a central role in blood coagulation and is always involved in cell-biomaterial interactions. Further, I monitor equilibrium coverage fluctuations of sodium dodecyl sulfate and demonstrate a new approach to quantify the characteristic rate constants which is independent of mass transfer interference and long term drifts of the measured signal. This method has been investigated theoretically by Monte-Carlo simulations but so far there has been no sensor technology with a sufficient signal-to-noise ratio.rnSecond, I apply plasmonic nanoparticles as sensors for the determination of diffusion coefficients. Thereby, the sensing volume of a single, immobilized nanorod is used as detection volume. When a diffusing particle enters the detection volume a shift in the resonance wavelength is introduced. As no labeling of the analyte is necessary the hydrodynamic radius and thus the diffusion properties are not altered and can be studied in their natural form. In comparison to the conventional Fluorescence Correlation Spectroscopy technique a volume reduction by a factor of 5000-10000 is reached.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Der Free Fatty Acid Receptor 1 (FFAR1) ist ein G-Protein gekoppelter Rezeptor, welcher neben einer hohen Expression im Gehirn auch eine verstärkte Expressionsrate auf den β-Zellen des Pankreas aufweist. Diese Expressionsmuster machen ihn zu einem idealen Target für die Visualisierung der sogenannten β-Zell-Masse mittels molekularer bildgebender Verfahren wie der PET. Eine Entwicklung geeigneter Radiotracer für die β-Zell-Bildgebung würde sowohl für die Diagnostik als auch für die Therapie von Typ-1- und Typ-2-Diabetes ein wertvolles Hilfsmittel darstellen.rnAufbauend auf einem von Sasaki et al. publiziertem Agonisten mit einem vielversprechendem EC50-Wert von 5,7 nM wurden dieser Agonist und zwei weitere darauf basierende 19F-substituierte Moleküle als Referenzverbindungen synthetisiert (DZ 1-3). Für die 18F-Markierung der Moleküle DZ 2 und DZ 3 wurden die entsprechenden Markierungsvorläufer (MV 1-3) synthetisiert und anschließend die Reaktionsparameter hinsichtlich Temperatur, Lösungsmittel, Basensystem und Reaktionszeit für die nukleophile n.c.a. 18F-Fluorierung optimiert. Die abschließende Entschützung zum fertigen Radiotracer wurde mit NaOH-Lösung durchgeführt und die Tracer injektionsfertig in isotonischer NaCl-Lösung mit radiochemischen Ausbeuten von 26,9 % ([18F]DZ 2) und 39 % ([18F]DZ 3) erhalten.rnZusätzlich wurde ein Chelator zur 68Ga-Markierung an den Liganden gekoppelt (Verb. 46) und die Markierungsparameter optimiert. Nach erfolgter Markierung mit 95 % radiochemischer Ausbeute, wurde der Tracer abgetrennt und in vitro Stabilitätsstudien durchgeführt. Diese zeigten eine Stabilität von mehr als 90 % über 120 min in sowohl humanem Serum (37 °C) als auch isotonischer NaCl-Lösung.rnMit einem ebenfalls synthetisierten fluoreszenzmarkierten Derivat des Liganden (Verb. 43) wurden erste LSM-Bilder an sowohl Langerhansschen Inseln als auch FFAR1-tragenden RIN-M Zellen durchgeführt, welche einen vielversprechenden Uptake des neuen Liganden in die Zellen zeigen. Weitere Untersuchungen und biologische Evaluierungen stehen noch aus. Mit den Referenzsubstanzen wurden zusätzlich Vitalitätsstudien an Langerhansschen Inseln durchgeführt, um einen negativen toxischen Einfluss auszuschließen.rn